Cathode coating adhesionMonitoring & AlertsPilot coating line 2
Target experience · needs ADR-0006 sign-off Today · control is advice (A2) ← Design set Illustrative values
Pilot coating line 2Project section · Monitoring & Alerts

Monitoring & Alerts

Advisory 1 open incident · 1 monitor live · 2 coworkers on trigger · data fresh 11:06:14 IST

Live signals

live · Line historian · OPC UA gateway (read-only)
Bands from process specification PS-L2 rev D · select a signal to see where it comes from

Incident 9 · Zone 3 anneal advisory

open since 10:45 · acknowledged · control plan waiting for approval
  1. Anneal watch v2monitor · L0raised 10:54
    AdvisoryAlert record · Incident 9

    Zone 3 at 603 °C for 9 min during roll 17-04, above the 595 °C advisory band

    Rule
    anneal-watch/zone3-advisory revision 3 · TC-3B > 595 °C for ≥ 9 min
    Evidence window
    10:45–10:54 · 540 samples at 1 Hz ·
    Band source
    Process specification PS-L2 rev D §3.2 · normal ≤ 595 · advisory 595–605 · alarm > 605 °C
    Linked
  2. EElidyneexplanation · answered from records10:58grounded in 4 records

    Why is zone 3 above its band at an unchanged setpoint?

    The setpoint has not moved: zone 3 has been at since the process change. At 10:41 the web speed dropped from to , which lengthens the dwell in zone 3. For 1.3 m/min the twin predicts a strip temperature of , against at 1.5 m/min. TC-3B read at 10:54: the residual is against the 1.3 m/min prediction, inside the twin's 95 % band, and against 1.5 m/min, outside it.

    The companion thermocouple TC-3A reads , within 1 °C of TC-3B, so this is not a sensor fault. Heater duty has held at 64 % since 10:41, so the oven is not overshooting; the web is spending longer in it.

    Likely explanation, not a conclusionThe twin re-run at 1.3 m/min and the PT-200 test on roll 17-04 decide it.
    Observed TC-3BTwin · 1.5 m/min · 95 % bandTwin · 1.3 m/min · 95 % bandAdvisory 595 °C
    Figure 1. Zone 3 temperature (TC-3B), 10:30–11:06, against the twin's 95 % bands at both web speeds. Shaded column: alert window 10:45–10:54. The dashed band is the twin at 1.3 m/min, confirmed by Run 1 at 11:04.
    Hover the figure, or focus it and use the arrow keys, to read one sample.
    Checked and set aside
    • Sensor fault: TC-3A reads 602 °C, within 1 °C of TC-3B, and neither shows drift or spikes over the last 6 h.
    • Heater runaway: zone 3 heater duty 64 %, steady since 10:41; zones 2 and 4 on their setpoints.
    • Elsewhere on the line: coating thickness 62 µm and dry-room humidity 1.1 % RH, both normal; nothing else moved at 10:41.
    • Not ruled out: adhesion on roll 17-04. The last PT-200 (0.47 N/mm) is from roll 17-03, tested 10:32; roll 17-04's test comes after the roll.
    Updated 11:04 by Run 1 of “Oven twin at 1.3 m/min”: the re-run confirms this explanation, residual +2 °C. It stays an explanation until the PT-200 result on roll 17-04.
    1 Historian window 10:45–10:54 · 2 Twin prediction, Investigation 12 · 3 Web speed record, 10:41 · 4 Process specification PS-L2 rev D · 5 Run 1, Oven twin at 1.3 m/min
  3. EElidyneproposal10:59
    L1execute with approval · spawns an investigation from this incident

    Re-run the oven twin at 1.3 m/min

    Start investigation “Oven twin at 1.3 m/min” · plan v1 · 0.6 CU · runs on the shared CPU pool
    1. Set the oven thermal model to the observed conditions: web speed 1.3 m/min, zone 3 setpoint 585 °C, heater duty 64 %
    2. Solve the strip temperature through zones 1–4 with its 95 % band
    3. Compare the zone 3 prediction with the historian window 10:45–10:54
    Readstwin · 4 streams · 1 window
    Writesa twin revision, not adopted
    Estimate0.45–0.6 CU · reserved at p90
    Approved by you · 11:00 · 0.6 CU reserved
  4. Run 1 · Oven twin at 1.3 m/minfinished 11:042 m 10 s · 0.5 CU of 0.6 reserved · shared CPU pool

    Twin re-run finished: predicted at 1.3 m/min → residual , inside band

    The 1.3 m/min operating point is recorded as twin revision r2, not adopted. Anneal watch v2 keeps reading the raw thermocouple; v3, in shadow, reads the twin's strip temperature.
  5. EElidynelive control plan · Workbench11:05
    Proposal · nothing has runplan v1 · checked · 0 holes

    Bring zone 3 back inside the specification and hold roll 17-04 for its peel test

    Steps
      One press approves the whole plan. Nothing runs until you execute it.
    • EElidynemonitor review11:06
      Shadow · never acts

      Anneal watch v3 (proposed, running in shadow since 06:00 on 21 Sep · never acts)

      Compared with v2, live, on the same 5 streams over the last 24 h (11:06 on 21 Sep to 11:06 today). v3 reads the twin's strip temperature instead of the raw thermocouple.

      Last 24 hv2 livev3 shadow
      Alerts raised62
      Later cleared as noise40
      Valid alerts missed00
      Zone 3 advisory raised10:5410:51 · 3 min earlier
      valid alertcleared as noise
      ›What changed in v3 · 3 rule changes
      • Zone advisory: the twin's strip temperature (from TC-3B, web speed and heater duty) above 595 °C for 6 min, instead of raw TC-3B above 595 °C for 9 min. Air overshoots at roll changes and door purges stay quiet.
      • Thermocouple spikes: TC-3A and TC-3B must agree within 3 °C before any zone rule fires. Single-sample glitches stay quiet.
      • New combined rule: web speed below 1.4 m/min for 5 min with zone 3 above 590 °C. This is what raised today's advisory 3 min earlier.
      ›All 6 alerts, side by side
      WhenWhatv2v3Outcome
      Promotion needs your approval · v3 stays at L0
    Run an analysis on live data
    Incident 9 · Pilot coating line 2 · since 10:45
    Instant answers from records · Workbench plans a Run for approval